When steam loads
fluctuate rapidly or when a sudden high steam demand occurs on any steam
system, instability due to low steam pressure can be the result. The
Clayton Back Pressure Regulator is designed to prevent this by ensuring
that the pressure in the steam generator does not fall below a preset
limit.
Back Pressure Regulating Valve
(models may vary from the one
shown
THE
CLAYTON BACK PRESSURE REGULATING VALVE
is
a self-operated steam pressure regulator which is mounted in the steam
outlet line from the Clayton Steam Generator. The valve taps it’s
actuating energy directly from the steam itself and ensures that a
minimum upstream pressure is maintained.
If
the upstream pressure falls below the set point the valve will starts to
close until the minimum desired pressure is achieved. The Clayton Back
Pressure Regulating Valve is extremely reliable and versatile.
ADVANTAGES
A sudden drop in
steam pressure is undesirable for several reason. In particular it can
produce ‘flash steam’ and water carryover. However by controlling the
minimum pressure, the steam generator system is maintained in a balanced
condition at all times. An added benefit of using the regulator is that
it allows faster heat up after initial start and faster recovery
following a period of overload.
By providing stable
operation of the steam system the Clayton Back Pressure Regulating Valve
also gives additional protection to the helical water coil.
MULTIPLE STEAM GENERATORS
On multiple steam
generator installations the Clayton Back Pressure Regulator will provide
stable operation on start-up and during operation and will maintain the
system in balance. On multiple installations separate regulators are
required on each steam generator.
|